Aligned to AQA Combined Science 8464 and AQA GCSE Chemistry 8462
To find out which products form at each inert electrode when different aqueous salt solutions are electrolysed, and to identify any gases made.
14 original questions, 36 marks. Try each one, then open the model answer and mark yourself against the marking points. Or print the sheet and mark it with the answers sheet. The full method is in the revision notes at the bottom.
Equipment: beaker or small plastic electrolysis cell; two graphite (carbon) rod electrodes; low-voltage DC power supply (about 4-6 V); connecting leads and crocodile clips; two small graduated tubes to collect gas; solutions such as copper(II) chloride, copper(II) sulfate, sodium chloride, sodium sulfate and potassium bromide; blue litmus paper; wooden splints; safety goggles.
Aisha and Tom electrolysed five solutions using graphite electrodes at 4 V. Each time they collected the gas over each electrode for 5 minutes and measured its volume in a small graduated tube.
Solution
Seen at cathode (negative)
Seen at anode (positive)
Volume of gas at cathode after 5 min in cm3
Volume of gas at anode after 5 min in cm3
Copper(II) chloride
Pink-brown coating
Bubbles; gas bleached damp blue litmus
0.0
2.9
Copper(II) sulfate
Pink-brown coating
Bubbles; gas relit a glowing splint
0.0
4.0
Sodium chloride
Bubbles; gas gave a squeaky pop
Bubbles; gas bleached damp blue litmus
8.6
6.2
Sodium sulfate
Bubbles; gas gave a squeaky pop
Bubbles; gas relit a glowing splint
8.4
4.1
Potassium bromide
Bubbles; gas gave a squeaky pop
Solution turned orange near the electrode
8.2
0.0
The questions
1
Explain why graphite is used for the electrodes.
2 marks
Show the model answer
Graphite conducts electricity and is inert, so it does not react with the solution or the products. This means the products only come from the ions in the solution.
Marking points
Conducts electricity
Inert / does not react, so does not affect the products
2
State the independent variable in this investigation and give one control variable.
2 marks
Show the model answer
Independent variable: the salt solution used. Control variable: the voltage of the power supply (or the type of electrode, or the concentration of the solution).
Marking points
Independent: the solution / salt used
Control: voltage, electrode type, concentration, volume or time
3
Chlorine is made when sodium chloride solution is electrolysed. Describe the hazard of chlorine, what could happen, and one way to reduce the risk.
3 marks
Show the model answer
Chlorine is a toxic gas. Breathing it in can irritate the lungs and cause coughing or an asthma attack. Only run the electrolysis for a few minutes in a well-ventilated room or a fume cupboard.
Marking points
Chlorine is toxic
Irritates lungs / eyes, may trigger asthma
Short time, good ventilation or fume cupboard
4
Describe how to test for each of these gases and give the positive result:
hydrogen
oxygen
chlorine
3 marks
Show the model answer
a) Hold a lit splint at the mouth of the tube: a squeaky pop. b) Put a glowing splint into the tube: it relights. c) Hold damp blue litmus paper in the gas: it turns red and then bleaches white.
Marking points
Hydrogen: lit splint gives a squeaky pop
Oxygen: glowing splint relights
Chlorine: damp litmus paper is bleached
5
Use the table to name the products at the cathode and at the anode when potassium bromide solution is electrolysed.
2 marks
Show the model answer
Cathode: hydrogen. Anode: bromine (it dissolves and makes the solution orange).
Marking points
Cathode: hydrogen
Anode: bromine
6
Explain why hydrogen, not sodium, is made at the cathode when sodium chloride solution is electrolysed.
2 marks
Show the model answer
The solution contains hydrogen ions from the water as well as sodium ions. Sodium is more reactive than hydrogen, so the hydrogen ions gain electrons instead and hydrogen gas is made.
Marking points
Water provides hydrogen ions
Sodium is more reactive than hydrogen, so hydrogen is discharged
7
Calculate the mean rate at which hydrogen was produced from sodium sulfate solution, in cm3 per minute. Give your answer to 2 significant figures.
2 marks
Show the model answer
1.7 cm3/min
Mean rate = volume / time
Mean rate = 8.4 / 5
Mean rate = 1.68
Mean rate = 1.7 cm3/min (2 significant figures)
Marking points
8.4 / 5
1.7 cm3/min
8
For sodium sulfate solution, calculate the ratio of the volume of gas at the cathode to the volume of gas at the anode. Give your answer to 2 significant figures.
2 marks
Show the model answer
2.0 (so about 2 : 1)
Ratio = volume at cathode / volume at anode
Ratio = 8.4 / 4.1
Ratio = 2.04...
Ratio = 2.0, so about 2 : 1
Marking points
8.4 / 4.1
2.0 (about 2 : 1)
9
The volume of chlorine collected from sodium chloride solution (6.2 cm3) is less than the volume of hydrogen (8.6 cm3), although they should be equal. Suggest why.
2 marks
Show the model answer
Chlorine is slightly soluble in water, so some of it dissolves in the solution instead of collecting in the tube. Hydrogen is almost insoluble, so nearly all of it is collected.
Marking points
Chlorine dissolves in the water / solution
Hydrogen does not, so more of it is collected
10
In another experiment, Tom weighed the cathode before and after electrolysing copper(II) sulfate solution for 10 minutes. Its mass went from 12.46 g to 12.71 g. Calculate the mass of copper deposited each minute. Show your working.
3 marks
Show the model answer
0.025 g per minute
Mass of copper = 12.71 - 12.46 = 0.25 g
Mass per minute = 0.25 / 10
Mass per minute = 0.025 g/min
Marking points
Mass gained = 12.71 - 12.46 = 0.25 g
0.25 / 10
0.025 g/min
11
Higher tier
Write half equations for the reactions at each electrode when copper(II) chloride solution is electrolysed.
2 marks
Show the model answer
Cathode: Cu2+ + 2e- → Cu Anode: 2Cl- → Cl2 + 2e-
Marking points
Cu2+ + 2e- → Cu
2Cl- → Cl2 + 2e- (or 2Cl- - 2e- → Cl2)
12
Higher tier
Explain, in terms of electrons, why the reaction at the cathode is reduction and the reaction at the anode is oxidation. Use copper(II) chloride as your example.
3 marks
Show the model answer
At the cathode, copper ions gain electrons to become copper atoms. Gaining electrons is reduction. At the anode, chloride ions lose electrons to form chlorine molecules, and losing electrons is oxidation.
Marking points
Copper ions gain electrons at the cathode
Gain of electrons is reduction
Chloride ions lose electrons at the anode, which is oxidation
13
The gas tubes are only marked every 1 cm3, so Aisha and Tom had to estimate each reading between the marks. Suggest one improvement and explain why it helps.
2 marks
Show the model answer
Collect the gas in a narrower graduated tube or burette marked every 0.1 cm3. This has a better resolution, so each volume can be read more precisely.
Marking points
Tube / burette with finer scale divisions
Higher resolution so volumes are read more precisely
14
Plan an investigation to find out how the current affects the mass of copper deposited on a graphite cathode when copper(II) sulfate solution is electrolysed.
6 marks
Show the model answer
Clean and dry a graphite cathode and weigh it on a balance to 0.01 g. Set up a beaker of copper(II) sulfate solution with two graphite electrodes, connected in series with a DC supply, an ammeter and a variable resistor. Switch on and use the variable resistor to set the current to 0.2 A. Start a stopwatch and electrolyse for 10 minutes, keeping the current steady. Switch off, carefully remove the cathode, rinse it gently with water then propanone or let it dry, and weigh it again. The increase in mass is the copper deposited. Repeat with fresh solution and a cleaned cathode at 0.4, 0.6, 0.8 and 1.0 A. Keep the time, the volume and concentration of solution and the distance between the electrodes the same. Do each current three times and find the mean mass, then plot mean mass against current. Wear goggles because copper sulfate is harmful.
Marking points (any 6, with the method in a logical order)
Weigh the clean, dry cathode before
Graphite electrodes in copper(II) sulfate with DC supply and ammeter in series
Variable resistor (or power supply setting) used to change current; at least 5 values
Electrolyse for a fixed time
Rinse, dry and reweigh the cathode; mass gain = copper deposited
Control: time, concentration, volume, electrode spacing
Repeat each current and calculate a mean
Plot mass of copper against current
Goggles worn / handle copper sulfate carefully
How it is marked
5-6 marks: a clear plan that could be followed, with weighing before and after, a way of changing and measuring current, fixed time, control variables and repeats.
3-4 marks: the main idea of weighing the cathode at different currents is there, but some key detail is missing, such as how the current is measured or what is kept the same.
1-2 marks: one or two relevant steps, such as electrolysing copper sulfate or weighing an electrode, with no logical plan.
Revision notes: the method in full
Aim: To find out which products form at each inert electrode when different aqueous salt solutions are electrolysed, and to identify any gases made.
Equipment
beaker or small plastic electrolysis cell
two graphite (carbon) rod electrodes
low-voltage DC power supply (about 4-6 V)
connecting leads and crocodile clips
two small graduated tubes to collect gas
solutions such as copper(II) chloride, copper(II) sulfate, sodium chloride, sodium sulfate and potassium bromide
blue litmus paper
wooden splints
safety goggles
Method
Pour about 50 cm3 of one salt solution into the beaker.
Fix the two graphite electrodes so they dip into the solution without touching each other.
Fill two small graduated tubes with the solution and turn one upside down over each electrode so that any gas is collected.
Connect the electrodes to the DC supply, set to about 4 V, and switch on.
Watch both electrodes. Record any bubbles, a coating on the electrode, or a colour change in the solution nearby.
After a few minutes, switch off and test any gas collected: a lit splint for hydrogen, a glowing splint for oxygen, damp blue litmus paper for chlorine.
Rinse the electrodes and beaker with water and repeat with each of the other solutions.
Record your results in a table showing the product at the cathode (negative) and the anode (positive) for each solution.
Variables
Independent: The salt solution being electrolysed.
Dependent: The product at each electrode, identified by what is seen and by the gas tests.
Control: The type of electrode (graphite, inert) for every solution; The voltage of the power supply; The concentration and volume of each solution; The time the current runs for
Hazards
Hazard
What could happen
How to reduce the risk
Chlorine gas produced at the anode
Toxic; irritates the lungs and eyes, especially for people with asthma
Run the cell for only a short time in a well-ventilated room or fume cupboard and switch off as soon as the test is done
Copper(II) salt solutions
Harmful if swallowed and irritating to the eyes
Wear safety goggles and wash hands after the practical
Hydrogen gas
Small pop when tested with a flame; flammable
Only test very small volumes with a lit splint held at arm's length
Key points
At the cathode: if the metal is more reactive than hydrogen (sodium, potassium), hydrogen is made instead of the metal.
At the anode: if a halide ion is present you get the halogen (chlorine, bromine, iodine); otherwise oxygen is made from water.
Graphite electrodes are inert: they do not react, so they do not change the products.
Gas tests: hydrogen pops with a lit splint, oxygen relights a glowing splint, chlorine bleaches damp litmus paper.
Chlorine is slightly soluble in water, so less of it is collected than you might expect.
Cathode is negative and attracts positive ions; anode is positive and attracts negative ions.
Every question and data set here is original and written by Robinson Tuition. Aligned to AQA Combined Science 8464 and AQA GCSE Chemistry 8462; this is not an exam-board paper and is not endorsed by AQA.