Aligned to AQA Combined Science 8464 and AQA GCSE Biology 8461
To prepare a slide of plant cells, observe them with a light microscope, and use magnification to work out the real size of the cells.
14 original questions, 36 marks. Try each one, then open the model answer and mark yourself against the marking points. Or print the sheet and mark it with the answers sheet. The full method is in the revision notes at the bottom.
Equipment: light microscope with x4, x10 and x40 objective lenses; glass microscope slide and coverslip; onion; forceps; scalpel or small knife; iodine solution in a dropping bottle; mounted needle; paper towel; ruler marked in mm (or an eyepiece graticule); pencil and plain paper for a drawing.
Kofi set up a digital microscope at a total magnification of x400 and displayed the image of onion skin cells on a screen. He measured the length and width of five cells on the screen with a ruler.
Cell
Length of image in mm
Width of image in mm
A
113
27
B
97
23
C
126
31
D
104
25
E
118
29
The questions
1
Give two reasons why only a very thin layer of onion skin is used on the slide.
2 marks
Show the model answer
Light has to pass through the sample to reach the lens, so a thin layer lets light through. A thin layer is only one cell thick, so the cells do not lie on top of each other and each cell can be seen clearly.
Marking points
light needs to pass through the specimen
cells are not overlapping / only one layer of cells so individual cells can be seen
2
Kofi lowered the coverslip onto the slide slowly, holding it at an angle.
What problem does this prevent?
Why is iodine solution added to the onion cells?
2 marks
Show the model answer
It stops air bubbles being trapped under the coverslip.
It stains the cells so parts such as the nucleus and cell wall are easier to see.
Marking points
(a) stops air bubbles forming / being trapped
(b) stains the cell so the nucleus / structures show up more clearly
3
Kofi wants to compare the sizes of his five cells fairly. Give two things he must keep the same when measuring each cell.
2 marks
Show the model answer
He must keep the same total magnification for every cell, and he must measure every cell in the same direction, along its longest side.
Marking points
the same magnification / same objective lens
measure each cell along the same axis (e.g. longest side) / use the same ruler
4
Describe how to bring the onion cells into focus, starting with the slide clipped onto the stage.
3 marks
Show the model answer
Select the lowest power objective lens first. Watching from the side, turn the coarse focusing knob so the stage moves up close to the lens without touching it. Then look through the eyepiece and turn the coarse knob to move the stage away until the cells appear, and finish with the fine focusing knob to make the image sharp.
Marking points
start with the lowest power objective lens
move the stage up close to the lens while watching from the side (so the lens does not hit the slide)
look through the eyepiece and focus with the coarse knob, then the fine knob to sharpen
5
Give one hazard in this practical and explain how the risk from it can be reduced.
2 marks
Show the model answer
Iodine solution can irritate the eyes. Wearing eye protection and adding it with a dropping bottle reduces the chance of it getting into the eyes.
Marking points
a hazard named, e.g. iodine solution is an irritant / scalpel is sharp / coverslips can break
a matching control, e.g. wear eye protection / cut away from the body / handle coverslips by the edges
6
The microscope had an eyepiece lens of x10 and Kofi used an objective lens of x40. Calculate the total magnification.
1 mark
Show the model answer
x400
total magnification = eyepiece magnification × objective magnification
total magnification = 10 × 40
total magnification = x400
Marking points
10 × 40 = x400
7
Use the table and the magnification of x400 to calculate the real length of cell C in micrometres (µm).
1 mm = 1000 µm. Show your working.
3 marks
Show the model answer
Real length = 126 ÷ 400 = 0.315 mm, which is 0.315 × 1000 = 315 µm.
real size = image size ÷ magnification
real size = 126 mm ÷ 400
real size = 0.315 mm
0.315 mm × 1000 = 315
real length of cell C = 315 µm
Marking points
uses real size = image size ÷ magnification
126 ÷ 400 = 0.315 (mm)
converts to 315 µm
8
Calculate the mean real length of the five cells in micrometres (µm). Show your working.
3 marks
Show the model answer
Mean image length = (113 + 97 + 126 + 104 + 118) ÷ 5 = 558 ÷ 5 = 111.6 mm. Real length = 111.6 ÷ 400 = 0.279 mm = 279 µm.
total of image lengths = 113 + 97 + 126 + 104 + 118
total = 558 mm
mean image length = 558 ÷ 5
mean image length = 111.6 mm
mean real length = 111.6 mm ÷ 400
mean real length = 0.279 mm
0.279 mm × 1000 = 279
mean real length = 279 µm
Marking points
adds the five lengths and divides by 5 to get 111.6 mm
divides by the magnification: 111.6 ÷ 400 = 0.279 mm
279 µm
9
Higher tier
The real length of cell D is 260 µm. Give this length in metres, in standard form.
1 m = 1 000 000 µm.
2 marks
Show the model answer
260 ÷ 1 000 000 = 0.00026 m = 2.6 × 10-4 m
length in m = 260 µm ÷ 1 000 000
length in m = 0.00026 m
length = 2.6 × 10-4 m
Marking points
260 ÷ 1 000 000 = 0.00026 (m)
2.6 × 10-4 m
10
In a textbook photograph of a cheek cell, a scale bar 25 mm long is labelled 50 µm. Calculate the magnification of the photograph.
2 marks
Show the model answer
25 mm = 25 000 µm, and 25 000 ÷ 50 = x500.
image size = 25 mm = 25 × 1000 = 25 000 µm
magnification = image size ÷ real size
magnification = 25 000 µm ÷ 50 µm
magnification = x500
Marking points
converts to the same unit: 25 mm = 25 000 µm
magnification = 25 000 ÷ 50 = x500
11
Higher tier
Leila uses a different method to estimate cell size. At x400 the circle of light she can see (the field of view) is 0.45 mm across. Exactly three onion cells, lying end to end, fit across the middle of the field of view.
Estimate the length of one cell in µm. Show your working.
3 marks
Show the model answer
0.45 mm = 450 µm. Three cells fill this width, so one cell is 450 ÷ 3 = 150 µm long.
field of view = 0.45 mm × 1000 = 450 µm
length of one cell = field of view ÷ number of cells
length of one cell = 450 µm ÷ 3
length of one cell = 150 µm
Marking points
converts 0.45 mm to 450 µm
divides the field of view by the number of cells
150 µm
12
Kofi measured the cells on the screen with a ruler marked in mm.
Explain why he measured five cells rather than one.
Suggest a better way of measuring the cells and say why it is better.
3 marks
Show the model answer
Cells of the same type vary in size, so a mean of several cells gives a more representative value than one cell, which might be unusually large or small.
Use an eyepiece graticule that has been calibrated against a stage micrometer. The cells are then measured against a scale of known small divisions inside the microscope, which gives a more accurate length than holding a ruler against a screen.
Marking points
(a) cells differ in size so a mean of several is more representative / one cell may be untypical
(b) use an eyepiece graticule calibrated with a stage micrometer
(b) the scale is seen with the cell, with known small divisions, so the measurement is more accurate
13
Higher tier
Kofi could see the nucleus of each cell but could not see any ribosomes, even when he increased the magnification. Explain why.
2 marks
Show the model answer
A light microscope has a limited resolution, so two points closer together than about 0.2 µm cannot be seen as separate. Ribosomes are far smaller than this, so magnifying the image more just makes it bigger and blurrier without showing extra detail. An electron microscope, with much higher resolution, is needed.
Marking points
the resolution of a light microscope is too low / it cannot separate very small or close structures
ribosomes are smaller than the resolution limit, so more magnification only gives a bigger blurred image (an electron microscope is needed)
14
Plan an investigation to find out whether a leaf has more stomata on its upper surface or on its lower surface.
You should use a light microscope. Clear nail varnish can be painted onto a leaf, left to dry and peeled off with clear sticky tape to give a thin copy of the leaf surface.
6 marks
Show the model answer
Take one leaf from a plant, for example a privet or a geranium. Paint a small patch of clear nail varnish on the upper surface and a patch the same size on the lower surface, and leave them to dry. Press clear sticky tape onto each patch, peel off the varnish layer and stick each one onto its own labelled slide. Put the upper surface slide on the stage, start on the lowest power objective and focus with the coarse then fine knob, then switch to the x40 objective and refocus with the fine knob. Count the number of stomata in the whole field of view. Move to four more areas of the same peel and count again, then work out a mean number per field of view. Repeat for the lower surface slide using exactly the same magnification, so the field of view is the same area. Keep the leaf type and age the same and take both peels from the same leaf, and repeat the whole thing with several leaves from the same plant. Compare the mean counts: the surface with the higher mean has more stomata. If the field of view diameter is known, the number per mm2 can be calculated using πr2 for the area.
Marking points (any 6, with the method in a logical order)
nail varnish painted on upper and lower surfaces of the same leaf and allowed to dry
peel removed with clear tape and stuck onto a labelled slide
focus on low power first, then move to a high power objective and use the fine knob
count the stomata in the field of view
count in several different fields of view and calculate a mean
use the same magnification for both surfaces so the area counted is the same
control variables: same leaf / same type and age of leaf / same plant
repeat with several leaves to check repeatability
compare the means, or work out stomata per mm2 from the field of view area
How it is marked
5-6 marks: a full, logical plan that someone could follow: making the peels from both surfaces, focusing correctly, counting stomata in several fields of view at the same magnification, taking means, naming controls and saying how the results are compared.
3-4 marks: a workable plan with the main steps (peels, microscope, counting on both surfaces) but missing some detail such as repeats, means, same magnification or controls.
1-2 marks: a few relevant points, such as using nail varnish or looking at the leaf under a microscope, without a clear order or a way of comparing the two surfaces.
Revision notes: the method in full
Aim: To prepare a slide of plant cells, observe them with a light microscope, and use magnification to work out the real size of the cells.
Equipment
light microscope with x4, x10 and x40 objective lenses
glass microscope slide and coverslip
onion
forceps
scalpel or small knife
iodine solution in a dropping bottle
mounted needle
paper towel
ruler marked in mm (or an eyepiece graticule)
pencil and plain paper for a drawing
Method
Cut a small square of onion and peel off the very thin, see-through layer of skin from the inner surface using forceps.
Put a drop of water on the middle of a clean slide and lay the onion skin flat on it, smoothing out any folds.
Add one or two drops of iodine solution to stain the cells so the nucleus and cell wall show up.
Hold the coverslip at an angle at the edge of the liquid and lower it slowly with a mounted needle so that no air bubbles are trapped.
Soak up any extra liquid at the edges with a piece of paper towel.
Clip the slide onto the stage and select the lowest power (x4) objective lens.
Looking from the side, use the coarse focusing knob to raise the stage until it is close to the lens without touching it.
Looking through the eyepiece, use the coarse knob to move the stage away until the cells come into focus, then sharpen the image with the fine focusing knob.
Switch to a higher power objective and refocus with the fine knob only.
Measure the length of several cells (with an eyepiece graticule, or on a screen image), work out the real size of each and calculate a mean.
Make a clear pencil drawing of a few cells, label the cell wall, cytoplasm and nucleus, and write the magnification next to it.
Variables
Independent: The cell being looked at (a different cell is measured each time)
Dependent: The length of the image of each cell, measured in mm and converted to a real length in micrometres (µm)
Control: the same total magnification for every cell measured; every cell measured along its longest side; cells all taken from the same layer of the same onion; the same ruler or graticule used for every measurement
Hazards
Hazard
What could happen
How to reduce the risk
Iodine solution
can irritate the skin and eyes and stains skin and clothes
wear eye protection, use a dropping bottle and wash off any splashes straight away
Sharp scalpel and thin glass coverslips
cuts to the fingers, especially if a coverslip snaps
cut away from the body on a tile, handle coverslips by the edges and tell the teacher about any broken glass
Microscope lamp or mirror
using a mirror in direct sunlight can damage the eye
use the built-in lamp, or point the mirror at a window but never at the Sun
Key points
Magnification = size of image ÷ size of real object; learn it in all three arrangements
Get both sizes in the same unit before dividing: 1 mm = 1000 µm
Total magnification = eyepiece lens magnification × objective lens magnification
Always start on the lowest power objective, then move up and use only the fine knob at high power
Lower the coverslip at an angle to stop air bubbles, which look like black-edged circles
Pencil drawings: clear single lines, no shading, labels with ruled lines, magnification written on
Every question and data set here is original and written by Robinson Tuition. Aligned to AQA Combined Science 8464 and AQA GCSE Biology 8461; this is not an exam-board paper and is not endorsed by AQA.